Trending Topik

Batasan Parameter Standard Air Baku PLTU

Aliran proses yang umum ada di PLTU sebagai berikut: 

Air laut-Bak pengendapan/clarifier/sedimentation pond-Multi media filter (MMF)-Desalination (RO/MSF/MED)-Demineralization (mixed bed/single bed)-Condensate Water-Outlet deaerator/lnlet economizer-Boiler water/steam drum-Saturated steam/outlet drum-Superheated steam

  • Bak Pengendapan/Clarifier, berfungsi menurunkan kadar lumpur/suspended solid. Parameter standar umum outlet clarifier adalah:
  1. Turbidity, <5 NTU
  2. Total Suspended Solid (TSS), <10 ppm
  • Multi-Media Filter (MMF)/Activated Carbon/Sand Filter. Parameter standar umum outlet MMF adalah:

    1. Turbidity, <1 NTU
    • Desalination, berfungsi meminimalisir kandungan garam dengan prinsip filter membrane untuk RO dan distilasi untuk MED. Parameter standar umum outlet desalination adalah:
    Inlet SWRO
    1. Turbidity, <1 NTU
    2. Free Chlorine, <100 ppb
    3. Silt Density Index (SDI)<5
    Outlet SWRO
    1. pH, 6-8
    2. Conductivity, <800 µS/cm
    Outlet BWRO
    1. pH, 6-8
    2. Conductivity, <20 µS/cm
    • Demineralization, berfungsi meminimalisir kandungan mineral ion. Parameter standar umum outlet demineralization adalah:
    1. pH, 6-8
    2. Specific Conductivity, <1 µS/cm
    3. Silica (SiO2), <20 ppb
    4. Chloride (Cl-), <100 ppb
    • Condensate Water, air keluaran condenser yang merupakan kondensasi steam turbine menjadi cair. Parameter standar umum outlet condensate water adalah:
    1. pH, 9-9.6 (TD), 8.8-9.3 (AM/BJ)
    2. Conductivity/Specific Conductivity, <11 µS/cm
    3. Cation Conductivity<0.3 µS/cm (PCT)
    4. Chloride (Cl-), <100 ppb
    5. Silica (SiO2), <15 ppb (TD), <20 ppb (BK)
    6. Dissolved Oxygen (DO), <50 ppb
    7. Hardness Water, <1 ppb (air laut), <40 ppb (air sungai)
    8. Iron (Fe), <20 ppb
    • Deaerator/Economizer, deaerator berfungsi menurunkan dissolved gas sebelum masuk boiler, parameternya sama antara outlet deaerator & inlet economizer sebagai berikut:
    1. pH, 9-9.6
    2. Specific Conductivity, <11 µS/cm
    3. Iron (Fe), <30 ppb (TD), <20 ppb (BT)
    4. Hydrazine (N2H4), 10-30 ppb (TD), 30-50 ppb (AM)
    5. DO, <7 ppb
    6. Silica (SiO2), <20 ppb
    • Steam Drum/Boiler Water, air yang sudah dipanaskan dan treatment di steam drum namun masih dalam fase semi liquid-vapor (saturated steam) untuk siklus kembali ke boiler furnace (downcomer steam drum). Parameter standar umum boiler water adalah:
    1. pH, 9.2-10.5
    2. Specific Conductivity, <150 µS/cm (TD), <100 µS/cm (BK), <60 µS/cm (air sungai)
    3. Phospate (PO4), 0.5-3 ppm (TD), 2-10 ppm (BK)
    4. Chloride (Cl-), <2 ppm (TD), <1 ppm (BK)
    5. Silica (SiO2), <2000 ppb (TD), <800 ppb (AM)
    6. Iron (Fe), <250 ppb
    1. pH, 9-9.6
    2. Specific Conductivity, <11 µS/cm (TD), <15 µS/cm (BK)
    3. Silica (SiO2), <20 ppb
    4. Iron (Fe), <20 ppb
    5. Chloride (Cl-), <0.1 ppm
    Penamaan anion-cation conductivity dan spesific conductivity mengikuti hal berikut:
    • Anion conductivity yang sebenarnya adalah anion exchanged conductivity ---> sampel air dilewatkan resin bed anion exchanger (muatan negative) sehingga muatan ion yang tertangkap dari sampel air adalah positif seperti sodium (Na+) dan potassium (K+)
    • Cation conductivity/Acid conductivity yang sebenarnya adalah cation exchanged conductivity --->  sampel air dilewatkan resin bed cation exchanger (muatan positif) sehingga muatan ion yang tertangkap dari sampel air adalah negatif seperti chloride (Cl-), sulphate (SO42-)
    • Specific conductivity artinya mengukur seluruh ion (positif dan negatif) pada sampel air. Umumnya penyebutan cukup conductivity atau total conductivity

    Ingin Konsultasi dengan Tim Expert Website Silakan, KLIK

    Kutip Artikel ini Sebagai Referensi (Citation):
    Feriyanto, Y.E. (2021). Batasan Parameter Standard Air Baku PLTU, Best Practice Experience in Power Plant. www.caesarvery.com. Surabaya

    Referensi:
    [1] Feriyanto, Y.E. (2015). Best Practice Experience in Power Plant. Surabaya

    Previous
    « Prev Post